中文
含义
E4 为化霜温度传感器异常。该传感器安装在蒸发器上,检测化霜过程中的温度变化,用于判定化霜开始和结束时机。
常见原因
- 化霜传感器热敏电阻开路或短路
- 传感器未正确固定在蒸发器上
- 传感器线束被冰层挤压损坏
- 控制板化霜检测电路异常
自助排查
- 观察冷冻室后壁是否结厚冰,如结冰严重说明化霜系统异常。
- 将冰箱断电化霜(至少 4-6 小时)后重新上电,观察是否恢复正常。
- 检查冷冻室后壁蒸发器附近的化霜传感器是否脱落或损坏。
- 如传感器损坏,需更换同型号化霜传感器,操作涉及拆卸内胆,建议联系海信售后。
English
Meaning
Defrost temperature sensor (on the evaporator) abnormal. This sensor is mounted on the evaporator and detects temperature changes during the defrost cycle.
Common Causes
- Defrost sensor thermistor open or short circuit
- Sensor not properly secured to the evaporator
- Sensor wiring harness crushed by ice buildup
- Control board defrost detection circuit abnormal
Self-Check Steps
- Check whether the rear wall of the freezer is heavily iced up; severe icing indicates a defrost system problem.
- Power off the refrigerator to defrost (at least 4-6 hours), then power on and check if normal operation resumes.
- Check whether the defrost sensor near the evaporator on the freezer rear wall has come off or is damaged.
- If the sensor is damaged, replace with the same type; this involves removing the inner liner, so contact Hisense service.