室内风机故障——电机不转、转速异常或反馈信号丢失。

常见原因

  1. 室内风机电机绕组烧毁或卡死
  2. 风机电容损坏(容量下降或击穿)
  3. 风机霍尔反馈元件损坏
  4. 电机启动器/驱动模块故障
  5. 风轮被异物卡住或积灰严重
  6. 主板至风机间的连接线松动或断裂

自助排查

  1. 断电后手动拨动风轮,检查是否卡滞
  2. 清理风轮及风机周围的灰尘和异物
  3. 用万用表测量风机电容容量是否在标称值±5%范围内
  4. 上电后观察风机是否短时启动后停止
  5. 以上无效则需更换风机电机或主控板

English

Meaning

Indoor fan motor fault — motor not spinning, abnormal speed, or RPM feedback signal lost.

Common Causes

  1. Burned-out or seized indoor fan motor winding
  2. Damaged fan capacitor (reduced capacitance or shorted)
  3. Faulty Hall-effect RPM sensor
  4. Motor starter/driver module failure
  5. Fan wheel obstructed by debris or heavy dust buildup
  6. Loose or broken wiring between mainboard and fan motor

Self-Check Steps

  1. Power off and manually rotate the fan wheel to check for binding
  2. Clean dust and debris from the fan wheel and surrounding area
  3. Measure the fan capacitor with a multimeter; should be within ±5% of the rated value
  4. Power on and observe if the fan briefly starts then stops
  5. If none of the above work, replace the fan motor or main control board