中文
含义
E6 为冷藏室蒸发器风机故障。该风扇将冷气从蒸发器吹向冷藏室,风扇不转会导致冷藏室不制冷,但冷冻室可能仍正常。
常见原因
- 风扇叶片结冰卡住
- 风扇电机线圈开路
- 门控开关故障导致风扇认为门开而不转
- 风扇转速反馈信号缺失
- 风扇电机轴承磨损
自助排查
- 打开冷藏室门,用手按压门控开关,倾听风扇是否启动运转。
- 如风扇不转,断电化霜(冰堵可能导致风扇卡住)后重新测试。
- 检查门控开关是否能正常弹起,开关损坏会导致风扇不启动。
- 如化霜后风扇仍不转,用万用表测量风扇供电是否正常。
- 风扇损坏需更换蒸发器风扇电机,涉及拆解风道,联系海信售后处理。
English
Meaning
Fresh food compartment evaporator fan motor fault. This fan blows cold air from the evaporator into the fresh food compartment.
Common Causes
- Fan blade iced up and stuck
- Fan motor winding open circuit
- Door switch fault causing fan to believe door is open
- Fan speed feedback signal missing
- Fan motor bearing worn
Self-Check Steps
- Open the fresh food door and press the door switch manually; listen for whether the fan starts running.
- If the fan does not run, power off and defrost (ice may be jamming the fan), then retest.
- Check whether the door switch clicks normally; a faulty switch will prevent the fan from starting.
- If the fan still does not run after defrosting, use a multimeter to check the fan power supply.
- If the fan is damaged, the evaporator fan motor needs replacement, which involves disassembling the duct; contact Hisense service.