含义

化霜温度传感器开路或短路,影响蒸发器化霜周期控制。

常见原因

  1. 化霜传感器插头松动或接触不良
  2. 传感器在化霜高温循环中老化损坏
  3. 传感器探头从蒸发器盘管上脱落
  4. 化霜加热器热辐射导致传感器读数偏高
  5. 线束在冷冻室内被冰层挤压断裂

自助排查

  1. 断电后重新插拔化霜传感器接头
  2. 用万用表测量传感器阻值,结霜低温时应较高
  3. 确认传感器探头紧贴蒸发器盘管
  4. 检查化霜加热器是否与传感器距离过近
  5. 若阻值异常,更换同型号化霜传感器

English

Meaning

Defrost temperature sensor open or short circuit. Affects evaporator defrost cycle control.

Common Causes

  1. Loose or poor contact of the defrost sensor connector
  2. Sensor degraded from repeated defrost high-temperature cycles
  3. Sensor probe detached from the evaporator coil
  4. Thermal radiation from the defrost heater causing elevated sensor readings
  5. Wiring pinched or broken by ice buildup inside the freezer

Self-Check Steps

  1. Power off and reseat the defrost sensor connector
  2. Measure sensor resistance with a multimeter; should be high at frost temperatures
  3. Verify the sensor probe is tightly attached to the evaporator coil
  4. Check if the defrost heater is positioned too close to the sensor
  5. Replace with the same type of defrost sensor if resistance is abnormal