03

03 - 夏普 空调

中文

含义

室外盘管温度传感器故障。室外冷凝器/蒸发器管温热敏电阻异常,影响系统除霜控制、制冷/制热模式切换及高压保护逻辑判断。

常见原因

  1. 室外管温热敏电阻开路或短路
  2. 传感器线束被老鼠咬断或老化脆裂
  3. 室外机接线端子腐蚀导致接触电阻增大
  4. 探头位置脱离铜管导致检测温度偏差
  5. 雷击或浪涌损坏传感器及其分压电路

自助排查

  1. 断电后打开室外机电控盒,测量管温传感器阻值
  2. 检查传感器到主板线束有无断裂、破损
  3. 确认传感器探头紧贴铜管并用金属夹固定良好
  4. 更换同规格室外管温传感器

English

Meaning

Outdoor coil temperature sensor failure. The outdoor condenser/evaporator pipe thermistor is abnormal, affecting defrost cycle control, cooling/heating mode switching, and high-pressure protection logic.

Common Causes

  1. Open or short-circuited outdoor pipe thermistor
  2. Sensor harness chewed by rodents or cracked from weather exposure
  3. Corroded outdoor unit terminal block increasing contact resistance
  4. Sensor probe detached from the copper tube causing inaccurate readings
  5. Lightning surge damage to the sensor or its voltage divider circuit

Self-Check Steps

  1. Power off, open the outdoor unit electrical box, and measure the pipe thermistor resistance
  2. Inspect the sensor wiring harness for breaks or damage
  3. Confirm the sensor probe is firmly attached to the copper tube with its metal clip
  4. Replace with the correct outdoor pipe temperature sensor specification