中文
含义
压缩机过热保护。压缩机内部温度过高,热保护器(内置PTC或双金属片)动作切断压缩机电源,或排气温度传感器检测到超限温度。
常见原因
- 制冷剂严重不足导致压缩机回气冷却不足,温度急剧升高
- 压缩机运转电流过大且长期持续
- 压缩机频繁启停(短循环),每次启动大电流叠加温升
- 压缩机冷冻油不足或变质,无法有效带走内部热量
- 室外机散热不良导致压缩机环境温度过高
自助排查
- 停机等待30分钟让压缩机冷却,然后重启观察是否能恢复正常运行
- 清洗室内机滤网和室外机散热翅片,改善换热
- 检查制冷系统压力,确认制冷剂是否不足
- 若频繁过热保护,需检查压缩机运行电流和排气温度,排除压缩机内部故障可能
English
Meaning
Compressor overheat protection. The internal temperature of the compressor is too high — the thermal protector (built-in PTC or bimetallic strip) has tripped, or the discharge temperature sensor has detected an overtemperature condition.
Common Causes
- Severely low refrigerant charge reducing suction gas cooling of the compressor, causing rapid temperature rise
- Prolonged high operating current sustained over time
- Frequent compressor short-cycling, each startup surge adding cumulative temperature rise
- Insufficient or degraded compressor oil unable to effectively carry away internal heat
- Poor outdoor unit heat dissipation raising the ambient temperature around the compressor
Self-Check Steps
- Stop the AC for 30 minutes to allow the compressor to cool, then restart to see if normal operation resumes
- Clean the indoor air filter and outdoor coil fins to improve heat exchange
- Check system pressures to determine whether refrigerant is low
- If overheat protection recurs frequently, measure compressor running current and discharge temperature to rule out internal compressor damage