中文
含义
UV杀菌灯故障。净水器末端UV杀菌灯无法正常工作,出水可能存在微生物安全风险。
常见原因
- UV-LED灯珠寿命耗尽——典型寿命约8000-12000小时
- UV灯珠焊接点老化开裂导致接触不良
- UV驱动电路恒流源损坏导致供电异常
- 石英玻璃套管结垢阻挡紫外线穿透
- UV灯珠过热——散热不良导致热衰减
自助排查
- 进入UV灯测试模式——观察UV灯工作指示灯是否正常
- 查看累计工作时间是否已超过UV灯珠额定寿命
- UV灯工作时外壳应有微热——完全不热说明未工作
- 拆卸UV灯组件检查石英管表面是否有结垢
- 若UV灯珠寿命耗尽——更换UV模组总成
English
Meaning
UV sterilization lamp failure. The terminal-stage UV-C lamp is not functioning, potentially compromising microbiological water safety.
Common Causes
- UV-LED chip reached end of service life — typically 8,000-12,000 hours
- Cracked solder joints on the UV LED causing intermittent connection
- Failed constant-current driver circuit for the UV module
- Scaled quartz glass sleeve blocking UV transmission
- UV LED overheating — thermal degradation from poor heat dissipation
Self-Check Steps
- Enter the UV lamp test mode and check if the working indicator lights up
- Check the accumulated operating time against the UV LED’s rated lifespan
- The UV module housing should feel slightly warm during operation — no warmth indicates it is not running
- Remove the UV module and inspect the quartz sleeve for scaling
- If the UV LED has reached end of life, replace the entire UV module assembly