中文
含义
燃气泄漏/制冷剂泄漏检测报警。空调内置的气体传感器检测到制冷剂(R32/R290等可燃制冷剂)浓度异常升高,系统进入安全保护模式并强制停机。此故障关乎安全,不可忽视。
常见原因
- 制冷系统管路存在微漏点,制冷剂缓慢泄漏被传感器捕获
- 空调安装时扩口连接处未拧紧或喇叭口制作不合格
- 蒸发器或冷凝器铜管被腐蚀穿孔,制冷剂泄漏
- 气体传感器本身误报(灵敏度漂移或老化)
- 使用环境中有其他气体(如酒精、燃气灶泄漏)导致误触发
自助排查
- 立即关闭空调并开窗通风,不要在该区域使用明火或电器开关
- 使用电子检漏仪检查室内机管路接头有无制冷剂泄漏
- 用肥皂水涂抹在各管路连接处,观察是否有气泡产生
- 若检测到明显泄漏,必须由专业维修人员修复漏点并补充制冷剂
English
Meaning
Gas leak / refrigerant leak alarm. The built-in gas sensor detects an abnormally high concentration of refrigerant (R32/R290 or other flammable refrigerant). The system enters safe mode and forcibly shuts down. This is a safety-critical fault and must not be ignored.
Common Causes
- Small leak in the refrigerant circuit — slow refrigerant loss detected by the sensor
- Loose flare nut connection or poorly formed flare during AC installation
- Corroded evaporator or condenser copper tube developing a pinhole leak
- False alarm from a drifted or aged gas sensor
- Other environmental gases (alcohol vapors, gas stove leakage) triggering the sensor
Self-Check Steps
- Immediately turn off the AC and ventilate the room — do not use open flames or operate electrical switches in the area
- Use an electronic leak detector to check the indoor unit pipe connections for refrigerant leakage
- Apply soap solution to all pipe joints and look for bubbles indicating leakage
- If a leak is confirmed, a qualified technician must repair the leak point and recharge the refrigerant