中文
含义
水质传感器异常。净水器出水水质检测传感器读数异常或持续显示不合格水质。
常见原因
- 水质传感器(TDS/电导率探头)表面结垢影响测量精度
- RO膜穿孔或密封圈失效导致脱盐率下降
- 后置活性炭滤芯未冲洗干净——新装滤芯初期炭粉渗出
- 水质传感器连接排线松动或受潮
- 传感器长期未校准导致零点漂移
自助排查
- 放水冲洗3-5分钟后再检测水质——排除管路滞留水
- 拆下水路中的水质传感器探头——用柠檬酸溶液去除结垢
- 检查RO膜使用时间是否已超期——超过24个月建议更换
- 新换滤芯后多冲洗10分钟——炭粉冲洗干净后水质会改善
- 用TDS笔手动测量对比——确认传感器是否需要校准
English
Meaning
Water quality sensor anomaly. The output water quality sensor reading is abnormal or continuously shows unacceptable purity levels.
Common Causes
- Scaled TDS/conductivity probe surface degrading measurement accuracy
- Perforated RO membrane or failed seal ring causing reduced rejection rate
- Post-activated carbon filter not flushed — carbon fines leaching from a new filter
- Loose or moisture-affected water quality sensor ribbon cable
- Zero-point drift from prolonged use without calibration
Self-Check Steps
- Flush the system for 3-5 minutes before retesting — stagnant water in the lines may give false readings
- Remove the sensor probe and descale with citric acid solution
- Check if the RO membrane is overdue — replace if in service over 24 months
- After installing new filters, flush for 10 extra minutes to clear carbon fines
- Cross-check with a handheld TDS meter to determine if the sensor needs calibration