中文
含义
主控制板(PCB)检测到自身硬件异常或组件通信失败,无法正常控制电机、电池及传感器系统。
常见原因
- 机器进水或受潮导致PCB短路或腐蚀
- 电源管理芯片损坏,供电电压异常
- 板载MOSFET击穿,电机驱动电路失效
- PCB焊点因振动疲劳出现裂纹,接触不良
- 静电放电(ESD)损坏控制板敏感元件
自助排查
- 断开充电器并取下电池(如可拆卸),等待1分钟后重新安装
- 检查机器外壳有无液体进入痕迹,尤其注意按键和充电口附近
- 尝试长按电源键15秒进行硬件复位
- 清洁电池触点并检查主板连接线是否松动
- 若复位无效,E08通常需要更换PCB总成,请送修
English
Meaning
The main control board (PCB) has detected a hardware abnormality or component communication failure, preventing normal control of the motor, battery, and sensor systems.
Common Causes
- Liquid ingress or moisture causing PCB short circuits or corrosion
- Faulty power management IC delivering abnormal supply voltage
- Blown onboard MOSFET causing motor drive circuit failure
- Solder joint cracks from vibration fatigue, causing intermittent contact
- Electrostatic discharge (ESD) damaging sensitive components on the control board
Self-Check Steps
- Disconnect the charger and remove the battery (if detachable), wait 1 minute, then reinstall
- Inspect the machine casing for signs of liquid ingress, especially near buttons and the charging port
- Try a hardware reset by pressing and holding the power button for 15 seconds
- Clean battery terminals and check for loose wiring connectors on the main board
- If the reset does not clear E08, the PCB assembly typically needs replacement — contact Dyson service