含义
出水/冲洗电磁阀故障。废水阀或出水电磁阀动作异常,导致废水比例失调、无法冲洗或不出纯水。
常见原因
- 废水电磁阀膜片堵塞——废水排放量减少导致RO膜背压过高
- 电磁阀线圈短路或断路
- 冲洗阀复位弹簧断裂导致阀芯不复位
- 控制板驱动电路异常——电磁阀持续通电或完全无电
- 阀体内进水结垢导致机械卡滞
自助排查
- 进入冲洗模式——观察电磁阀是否有动作声
- 检查废水排水量是否正常——废水管排水过少可能阀堵塞
- 拆下电磁阀检查阀芯是否卡滞——用柠檬酸清洗水垢
- 测量线圈电阻值与标称值对比判断好坏
- 冲洗电磁阀卡在常开位置会导致废水不停流——需更换
English
Meaning
Outlet/flush solenoid valve failure. The waste water valve or outlet solenoid behaves abnormally, causing imbalanced waste water ratio, failed flushing, or no pure water output.
Common Causes
- Clogged waste water solenoid diaphragm — reduced drainage causing excessive RO membrane back pressure
- Short-circuit or open-circuit solenoid coil
- Broken flush valve return spring preventing valve core reset
- Faulty control board drive circuit — solenoid continuously energized or completely unpowered
- Internal scale buildup in the valve body causing mechanical binding
Self-Check Steps
- Enter flush mode and listen for the solenoid clicking
- Check the waste water flow rate — insufficient drainage indicates a clogged valve
- Remove the solenoid and check the valve core for binding — clean with citric acid
- Measure coil resistance and compare with the rated value to determine coil health
- If the flush valve is stuck open, water will drain continuously — replace the valve