E7

E7 - 飞利浦 空气净化器

中文

含义

UV杀菌灯异常。净化器的紫外线杀菌灯无法点亮或杀菌功能失效。

常见原因

  1. UV灯管寿命耗尽——典型工作寿命约8000-10000小时
  2. UV灯管两端电极老化或灯丝断裂
  3. UV灯管镇流器/电子触发器损坏
  4. UV灯管连接器松动或接触不良
  5. UV灯管玻璃管破裂漏气

自助排查

  1. 在黑暗环境中透过观察窗查看UV灯是否亮起(紫色光)
  2. 记录净化器累计使用时间,判断UV灯是否超过使用寿命
  3. 断电后重新插拔UV灯管连接器
  4. 检查灯管两端是否有发黑——严重发黑表明电极已损耗
  5. 若灯管正常但UV故障仍在,需检查或更换镇流器

English

Meaning

UV sterilization lamp anomaly. The purifier’s UV-C lamp fails to illuminate or the sterilization function is inactive.

Common Causes

  1. UV lamp reached end of service life — typically 8,000-10,000 operating hours
  2. Aged or broken electrode filaments at both ends of the lamp
  3. Faulty UV lamp ballast or electronic igniter
  4. Loose or corroded UV lamp connector socket
  5. Cracked or broken UV lamp tube causing gas leakage

Self-Check Steps

  1. Look through the observation window in a dark room to check if the UV lamp glows (purple light)
  2. Check the purifier’s accumulated operating time against the UV lamp’s rated lifespan
  3. Power off, then reseat the UV lamp connector
  4. Inspect both ends of the lamp for severe blackening — indicates electrode depletion
  5. If the lamp appears good but the UV function is still flagged, inspect or replace the ballast

更多 飞利浦 空气净化器 错误代码