E3

E3 - 老板电器 油烟机

中文

含义

温度传感器(NTC)短路报警。主控读取到NTC温度传感器的电阻值接近0Ω(低于最低检测范围),判断传感器处于短路状态。

常见原因

  1. NTC热敏电阻两引脚被油污或水分导通导致短路
  2. 传感器引线绝缘皮破损,两根导线碰触短路
  3. NTC元件被击穿或失效(短路态)
  4. 接插件内部引脚间短路(进水或异物)
  5. 主板上NTC检测电路滤波电容击穿

自助排查

  1. 断电后清理传感器探头附近的油污和水分,用酒精擦拭后晾干
  2. 检查传感器引线是否有破损、裸露铜线,用电工胶带隔离或更换线束
  3. 用万用表电阻档测量NTC两端阻值,正常应有一定阻值(10kΩ或100kΩ量级),若接近0Ω则短路
  4. 拔下NTC插头后测量主板侧接口对地电阻,判断是否为电路板原因
  5. 若传感器本体短路,需更换NTC热敏电阻

English

Meaning

Temperature sensor (NTC) short circuit alarm. The main control reads near-zero resistance from the NTC sensor — below the minimum detection range — indicating a short circuit condition.

Common Causes

  1. NTC thermistor leads bridged by grease or moisture causing a short
  2. Damaged sensor wire insulation with exposed copper conductors touching
  3. NTC element breakdown or failure (short-circuit mode)
  4. Short circuit between connector pins due to water ingress or debris
  5. Failed filter capacitor in the NTC detection circuit on the mainboard

Self-Check Steps

  1. Power off, then clean grease and moisture from the sensor probe area with alcohol; allow to dry thoroughly
  2. Inspect sensor wiring for damaged insulation or exposed copper; tape or replace the harness
  3. Measure NTC resistance with a multimeter — a normal reading is in the kΩ range (10kΩ or 100kΩ typical); near-zero indicates a short
  4. Disconnect the NTC sensor and measure the mainboard-side header resistance to ground to isolate board-level issues
  5. Replace the NTC thermistor if the sensor element itself is shorted

更多 老板电器 油烟机 错误代码